- Scrubber cooling water low-pressure alarm (<0.06 MPa, Press. switch calibration)
- Scrubber high level alarm (Float switch, cleaning).
- Scrubber low level alarm (Float switch, cleaning).
- Blower discharge gas high temp. (60°¢, Temp Sensor, Calibration).
- Blower discharge gas extra high temp trip (65 degree Celsius).
- Oxygen,0₂ Content high alarm (5%, Oxygen analyses filter change, calibration with nitrogen, pipeline cleaning).
- Oxygen content extra high trip (6%).
- Blower bearing temp high (temp Sensor, calibration).
- Control air low pressure alarm (0.4Mpa, pressure switch, calibration).
- Deck water seal low level alarm (FloatSwitch).
- Deck water seal supply water flow low pressure alarm, 2 pumps.
- Deck main line high pressure alarm.
- Deck main line low pressure alarm.
- Deck main line extra low pressure alarm & trip.
- Soot blower interlock (uptake valve, Steam cleansing).
- Deck Isolation valve (checking ceperation, Pneumatic cylinder).
- PV breaker (water level).
- Mast Riser (Flame trap cleaning).